0305
0305 / 0306 ROSEMOUNT MANIFOLDS
- Factory Assembled
- Pressure & Leak Tested
- 2, 3, and 5 valve configurations
- Compact, lightweight design
- Direct-mount capability
3100
Rosemount 3100 Series Ultrasonic Level Transmitters
- Non-contacting - No moving parts
- Push-buttons / HART Configuration
- Continuous level,volume flow
- Relay Output Option
- Easy to install and configure
- PVDF wetted material
- Rugged aluminum housing
2110
Rosemount 2110 Vibrating Fork Liquid Level Switch
- Virtually unaffected by flow, turbulence, bubbles, foam, vibration, solids content, coating, properties and product variations
- No calibration
- No moving parts - No maintenance
- Densities >0.6
- Viscosity up to 10,000cP
2120
Rosemount 2120 Vibrating Fork Liquid Level Switch
- Virtually unaffected by flow, turbulence, bubbles, foam, vibration, solids content, coating, properties and product variations
- No calibration
- No moving parts - No maintenance
- Densities >0.6
- Viscosity up to 10,000cP
- Side & Top Mount Versions
- ATEX Certified
- NAMUR, Relay, PNP Outputs
3095MFA
Rosemount 3095MFA Annubar Mass Probar Flow meter
- Integral Mount - No Impulse Lines
- Low Cost Installation
- Low Pressure Loss
- 4 Measurements in 1
- DP, Press, Temp, Flow
- Dynamically Compensates
- Accuracy: +/-0.9% Mass Flowrate
- Flow Turndown 10:1
- Sizes: 2" to 72" Nominal Bore
8800D
Rosemount 8800 MultiVariable Mass Vortex Flow meter
- MultiVariable Output - Temperature Compensated Mass Flow
- All-welded, non-clog design
- No Ports, Crevices, Gaskets
- Flanged & Reducer versions
- Steam Mass Flow Accuracy: +/-2%
- Flow Turndown Up to 40:1
- Sizes: 2" to 12" Nominal Bore
3095MFC
Rosemount 3095MFC Compact Orifice Mass Flow meter
- Integral Mount - No Impulse Lines
- Low Cost Installation
- 2 DIAMETER Straight Lengths
- 4 Measurements in 1
- DP, Press, Temp, Flow
- Dynamically Compensates
- Accuracy: +/-0.9% Mass Flowrate
- Flow Turndown 10:1
- Sizes: 2" to 12" Nominal Bore
3095
Rosemount 3095 Multivariable Mass Flow Transmitter
- 4 Measurements in 1
- DP, Press, Temp, Flow
- Reduced Installation Cost
- Dynamically Compensates
- Accuracy: +/-1% Mass Flowrate
- Flow Turndown 10:1
- ISO5167, BS1042, ASMI, AGA calcs
1595
Rosemount 1595 Conditioning Orifice Plates
- 2 DIAMETER Straight Lengths
- No More Installation Headaches
- Sizes 2” to 24”
- Improved Accuracy
1495
Rosemount 1495 Orifice Plates
- API, ASMI, AGA, ISO Standards
- Sizes 2” to 24”
- Universal, Ring Joint & Paddle
- Wide choice of Materials
- 1496 Carrier Range
8800D
Rosemount 8800 Vortex Flow meter
- All-welded, non-clog design
- No Ports, Crevices, Gaskets
- Available Wafer, Flanged,Reducer & Dual Sensor versions
- 1 Sensor for ALL meter sizes
- Gas Flow Accuracy: +/-1.35%
- Flow Turndown Up to 40:1
- Sizes: 2" to 12" Nominal Bore
8800D
Rosemount 8800 Vortex Flow meter
- All-welded, non-clog design
- No Ports, Crevices, Gaskets
- Available Wafer, Flanged,Reducer & Dual Sensor versions
- 1 Sensor for ALL meter sizes
- Accuracy: +/-1.35%
- Flow Turndown Up to 40:1
- Sizes: 2" to 12" Nominal Bore
3095MFA
Rosemount 3095MFA Annubar Mass Probar Flow meter
- Integral Mount - No Impulse Lines
- Low Cost Installation
- Low Pressure Loss
- 4 Measurements in 1
- DP, Press, Temp, Flow
- Dynamically Compensates
- Accuracy: +/-0.9% Mass Flowrate
- Flow Turndown 10:1
- Sizes: 2" to 72" Nominal Bore
3095MFC
Rosemount 3095MFC Compact Orifice Mass Flow meter
- Integral Mount - No Impulse Lines
- Low Cost Installation
- 2 DIAMETER Straight Lengths
- 4 Measurements in 1
- DP, Press, Temp, Flow
- Dynamically Compensates
- Accuracy: +/-0.9% Mass Flowrate
- Flow Turndown 10:1
- Sizes: 2" to 12" Nominal Bore
148
148 ROSEMOUNT TEMPERATURE TRANSMITTER
- Head Mounting
- Accuracy +/-0.3degC
- 1 Year Stability 0.15%
- RTD,TC,mV,ohms
- PC Programmable
- DIN Form B Head Mount
248
248 ROSEMOUNT TEMPERATURE TRANSMITTER
- Head & Rail Mounting
- Accuracy +/-0.2 degC
- 1 Year Stability 0.1%
- RTD,TC,mV,ohms
- 2 Point Referencing
- HART & PC Adjustable
- DIN Form B Head Mount
- Slim DIN Rail Mount 27mm
644
644 ROSEMOUNT TEMPERATURE TRANSMITTER
- Head & Rail Mounting
- Accuracy +/-0.15 degC
- 2 Year Stability
- RTD,TC,mV,ohms
- Sensor Match - Reduce Errors
- LCD Display Option
- HART & Fieldbus Options
648
648 ROSEMOUNT WIRELESS TEMPERATURE TRANSMITTER
- WirelessHART-Open Standard
- Field Mounted - No Wires
- No cables - Reduced Installed Cost
- Self Learning Secure Mesh Network
- RTD,TC,mV,ohms, 4-20mA
- Sensor Match - Reduce Errors
- LCD Display Option
3144P
3144P ROSEMOUNT TEMPERATURE TRANSMITTER
- Field Mounting
- Accuracy +/-0.1 degC
- 5 Year Stability
- RTD,TC,mV,ohms
- Dual Sensor Input
- LCD Display Option
- HART & Fieldbus Options
- HOT Back Up
- Safety certified to IEC 61508
848
848 ROSEMOUNT MULTI - INPUT TRANSMITTER
- Multi Input Temperature Transmitter
- Field Mounted
- ATEX Intrinsically Safe
- 8 Configurable Inputs
- RTD,TC,mV,ohms,4-20mA
- Fieldbus Output
- High Density Installations
0065
0065 ROSEMOUNT TEMPERATURE SENSORS & ASSEMBLIES
- RTD's & Thermocouples
- Barstock & Tubular Thermowells
- Wide Selection of Materials
- Flanged, Screwed, Surface Mount
- Integral & Remote Heads
3051S
3051S ROSEMOUNT WIRELESS PRESSURE TRANSMITTER
- WirelessHART-Open Standard
- Field Mounted - No Wires
- No cables - Reduced Installed Cost
- Self Learning Secure Mesh Network
- Accuracy 0.055%
- 5 year stability
- Rangeability 100:1
- LCD Display Option
3051
3051 ROSEMOUNT TRANSMITTER
- Industry first installed 5 year stability
- Absolute, Gauge & Diff Pressure
- Accuracy +/- 0.065%
- 5 year stability
- Rangeability 100:1
- HART & FOUNDATION fieldbus
- Coplanar platform, integration of dp flow elements, manifolds, diaphragm seals
- Safety Certified to IEC 61508
2051
2051 ROSEMOUNT TRANSMITTER
- Replacement for 1151 Transmitter
- Absolute, Gauge & Diff Pressure
- Accuracy +/- 0.075%
- 2 year stability 0.1%
- Rangeability 100:1
- HART & FOUNDATION fieldbus
- Coplanar platform, integration of dp flow elements, manifolds, diaphragm seals
2088
2088 ROSEMOUNT TRANSMITTER
- Absolute & Gauge Pressure
- Accuracy +/- 0.1%
- 1 year stability 0.1%
- Rangeability 20:1
- St.Steel & Hastelloy C
- Local Display Option
1199
1199 ROSEMOUNT Diaphragm Seal Systems
- Extreme hot and cold temperatures
- Corrosive applications
- Clogging or viscous processes
- Sanitary requirements
- Level, Flow, Pressure, Interface
3051S
3051S ROSEMOUNT PRESSURE TRANSMITTER
- Best in Class Accuracy +/- 0.025%
- Industry first - 10 year stability
- Industry first - 12 year warranty
- Rangeability 200:1
- Absolute, Gauge & Diff Pressure
- HART & FOUNDATION fieldbus
- Coplanar platform, integration of dp flow elements, manifolds, diaphragm seals
- Safety Certified to IEC 61508
3095
3095 Rosemount MultiVariable Mass Flow Transmitter
- 4 Measurements in 1
- DP, Press, Temp, Flow
- Reduced Installation Cost
- Dynamically Compensates
- Accuracy: +/-1% Mass Flowrate
- Flow Turndown 10:1
- ISO5167, BS1042, ASMI, AGA calcs
848T
848 ROSEMOUNT MULTI - INPUT WIRELESS TRANSMITTER
- WirelessHART-Open Standard
- Field Mounted - No Wires
- No cables - Reduced Installed Cost
- Self Learning Secure Mesh Network
- Multi Input Temperature Transmitter
- Field Mounted
- ATEX Intrinsically Safe
- 4 Configurable Inputs
- RTD,TC,mV,ohms,4-20mA
- High Density Installations
6081
ROSEMOUNT 6081 WIRELESS pH TRANSMITTER
- WirelessHART-Open Standard
- Field Mounted - No Wires
- No cables - Reduced Installed Cost
- Self Learning Secure Mesh Network
- pH & Redox Measurement
- Full DIagnostic Capabilities
- Auto Buffering
- ATEX Certified
8800D
Rosemount 8800 Vortex Flow meter
- All-welded, non-clog design
- No Ports, Crevices, Gaskets
- Available Wafer, Flanged,Reducer & Dual Sensor versions
- 1 Sensor for ALL meter sizes
- Accuracy: +/-0.65%
- Flow Turndown Up to 40:1
- Sizes: 2" to 12" Nominal Bore
8705-8711-8732E
Rosemount 8700 Series Electromagnetic Flow meter
- Flanged, Wafer & Hygenic Models
- No Pressure Drop
- No maintenance
- Wide choice of wetted parts
- Meter Verification Option
- Integral or Remote Transmitter
- Accuracy: +/-0.5%
- Sizes: 4mm to 900mm
1420
1420 ROSEMOUNT WIRELESS GATEWAY
- WirelessHART-Open Standard
- No cables - Reduced Installed Cost
- Self Learning Secure Mesh Network
- 100 Devices / Gateway
- Easy Network Expansion
- Modbus, OPC, HTTP Outputs
702
ROSEMOUNT 702 WIRELESS DISCRETE TRANSMITTER
- WirelessHART-Open Standard
- Field Mounted - No Wires
- No cables - Reduced Installed Cost
- Self Learning Secure Mesh Network
- SIngle or Dual Input
- Display Option
3300
Rosemount 3300 Guided Wave Radar Transmitter
- Level and Interface Capability
- Wide range of Probes & Materials
- Not effected by SG,DK,Viscosity
- Easy installation
- Ranges: 0.1m to 23m
- Accuracy: +/-5mm
5300
Rosemount 5300 Guided Wave Radar Transmitter
- Level and Interface Capability
- Wide range of Probes & Materials
- Not effected by SG,DK,Viscosity
- Easy installation
- High Temp & Pressure Options
- Ranges: 0.1m to 50m
- Accuracy: +/-3mm
5400
Rosemount 5400 Non Contact Radar Level Transmitter
- Patented Circular Polarisation
- Non-contacting - No moving parts
- Not effected by SG,DK,Viscosity
- Easy installation
- Cone & Rod Antennas
- Low & High Frequency Versions
- Ranges: 0.75m to 35m
- Accuracy: +/-3mm to 10mm
In House
Calibration
- From our Redditch workshop we offer a comprehensive, UKAS traceable, laboratory based calibration service. We can calibrate the vast majority of process instruments in use today including temperature, pressure, electrical, dimensional, force, mass, torque, pH, humidity, time and speed.
- Our Kent workshop as an approved Rosemount repair centre specializes in the calibration and configuration of their products, primarily pressure, temperature and level.
ARRC
APPROVED ROSEMOUNT REPAIR CENTRE
- Workshop facilities at our Kent branch provide an in-house Instrument repair service
- No matter the condition of your instruments the Rosemount Gold Service Repair will help you replace your transmitter at a fraction of the cost
- This service includes the repair and fitting of Diaphrgam Seals (Fast- track service available as all popular sizes of Diaphrgam Seal are always available ex stock).
2051L
Rosemount 2051L Level Transmitter
- Replacement for 1151 Transmitter
- Performance of 0.075% accuracy
- Welded fill fluid system provides best-in-class system reliability
- Flush and extended diaphragms
- HART & FOUNDATION fieldbus
- Multiple fill fluids and process wetted materials available
3051L
Rosemount 3051L Level Transmitter
- Performance of 0.075% accuracy
- Welded fill fluid system provides best-in-class system reliability
- Flush and extended diaphragms
- HART & FOUNDATION fieldbus
- Multiple fill fluids and process wetted materials available
3051S
Rosemount 3051S Liquid Level Transmitter
- Performance up to ±0.065%
- accuracy and 100:1 rangedown
- Multiple fill fluids and wetted materials available
- Level and volume units, process alerts
- Flush, 2-in. (50 mm), 4-in. (100 mm), and 6-in. (150 mm) extended diaphragms
5600
Rosemount 5600 Series Radar Level Transmitter
- Market leading sensitivity and unique signal processing features allow it to handle a wide range of process conditions
- High repeatability ensures an extremely reliable and accurate level transmitter, even in the toughest conditions
- No moving parts
- FOUNDATION ™ fieldbus or analog 4-20 mA superimposed with HART®
2160
Rosemount 2160 Wireless Level Switch
- WirelessHART vibrating fork liquid level switch combines Emerson’s wireless expertise with the Rosemount 2100 series vibrating short fork technology.
- The Rosemount 2160 continuously performs instrument health diagnostics of the fork and sensor. These diagnostics can detect external damage to the forks, internal damage to the sensor, excessive corrosion and over-temperature.
- The 2160 can withstand temperatures from -94 °F (-70 °C) up to 500 °F (260 °C) and pressures to 1450 psig (100 bar g).
- The Rosemount 2160 wireless vibrating fork liquid level switch extends the full benefits of PlantWeb® to previously inaccessible or uneconomical locations due to the high cost of wiring in a wide variety of challenging applications.